TM 9-2350-256-10
3-7. VISION DEVICES-Continued.
e.
M24/M24A1 Periscope.
(1)
Removal.
WARNING
·
Be very careful. Periscope cable
carries 16,000 volts. DO NOT
remove cable until system is
turned off.
·
Ensure MASTER BATTERY and
IR power switches (1) are turned
off.
CAUTION
Do not open hatch with M24, M24A 1,
or
AN/VVS-2(V)1A
periscope
installed.
(a)
Remove cable plug from receptacle (2) and connect to dummy receptacle (3).
3-38