TM 9-2350-256-103-12. OXYGEN CYLINDER AND REGULATOR VALVE REPLACEMENT-Continued.CAUTIONCap oxygen cylinder when regulator valve and gages (3) are detached. Keepfittings clean at all times.b.Installation.(1)Lay oxygen cylinder (7) between two strap assemblies (6).(2)Rotate oxygen cylinder (7) so valve outlet inside safety cap (4) is pointing up.(3)Tighten nut (5) on two strap assemblies (6) to secure oxygen cylinder (7).(4)Position regulator valve and gages (3) sothey can be easily read.(5)Aline valve (3) fitting to oxygen cylinder (7)and tighten nut (2).(6)Refer to TM 9-237 for regulator valveoperation instructions.3-54