12. Place red lead of multimeter in socket F of wire 15 and black lead to ground. Turn MASTER switch on
and check for voltage. Turn MASTER switch OFF. If voltage is present, replace main lighting switch
(see WP 0159 00). If voltage is not present, go to step 13.
13. Reconnect main lighting and master relay wiring harness to main lighting switch. Disconnect wire 15
of main lighting and master relay wiring harness at connector. Place red lead of multimeter in female
connector of wire 15 and black lead to ground. Turn MASTER switch on and check for voltage. Turn
MASTER switch OFF. If voltage is present, repair/replace wire 15 of main lighting and master relay
wiring harness (see WP 0219 00). If voltage is not present, repair/replace wire 10 of main lighting and
B.O. selector switch wiring harness (see WP 0218 00).