TM 9-2350-256-20-1
0096 00
ITEM
INTERVAL
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY
SERVICED
AVAILABLE IF:
a. Service hydraulic reservoir oil filter (see WP 0420 00).
b. Inspect hydraulic lines and fittings for leaks, damage, and
Class III leak present.
c. Operate system and check for unusual noises or other defects.
44
Main Winch
a. Clean and lubricate cable (refer to TM 9-2350-256-10).
45
Hoist Winch
a. Clean and lubricate stayline cable in accordance with WP 0097
46
Hoisting Boom
and Deck
Attachments
b. Inspect boom yoke/pulley cotter pins. Replace if damaged or
Cotter pins missing or
missing (see WP 0414 00).
damaged.
47
M8A3 Gas/Par-
ticulate Filter
Unit
WARNING
The unit commander or senior officer in charge
of maintenance personnel assigned to remove
and dispose of contaminated gas filters must
prescribe necessary protective clothing to
be worn during this operation. They must
also prescribe necessary safety measures to
be followed including the decontamination
operation that must be performed before new gas
filters are installed in housing assembly (refer to
TM 3-220).
a. Check that air flow is 3.0 to 4.5 standard cubic feet/minute (scf/m)
or 2.1 to 4.5 inch water gage (IWG) at each station using the M39
Tester (item 57, WP 0490 00).
0096 00-25