TM 9-2350-256-20-2
0150 00
14. Disconnect ground strap (28) by removing self-locking nut (34) and flat washer (35).
WARNING
To avoid damage to equipment and injury to personnel, generator must be supported.
15. Place board under end of generator (32) for support.
16. Cut lockwire (36) and remove four screws (37), four flat washers (38), and generator cradle (39).
17. Separate bracket (40) from generator cradle (39) by removing self-locking nut (41) and flat washer (42).
18. Remove generator (32) by turning counterclockwise.
19. Remove generator exhaust boot (31).
0150 00-5