TM 9-2350-256-20-2
0162 00
Disassembly
1.
Remove relay switch cover (6) and gasket (7) by removing 16 screws (8) and 16 lockwashers (9).
2.
3.
Remove two diodes (13) by removing two screws (14), two nuts (15), and six lockwashers (16).
4.
Remove 3 connectors (17) and 3 gaskets (18) by removing 12 screws (19) and 12 lockwashers (20).
5.
Remove bracket assembly (21) by removing two screws (22), two nuts (23), two lockwashers (24), two loop clamps (25),
two screws (26), two nuts (27), and two lockwashers (28).
6.
Remove screw (29), lockwasher (30), and nut (31).
7.
Remove cap assembly (32), screw (33), and lockwasher (34).
8.
Remove three screws (35), three nuts (36), three lockwashers (37), and rheostat (38).
Assembly
1.
Install rheostat (38), using three screws (35), three lockwashers (37), and three nuts (36).
2.
Install cap (32), lockwasher (34), and screw (33).
3.
Install screw (29), lockwasher (30), and nut (31).
4.
Install bracket assembly (21) using two screws (26), two lockwashers (28), two nuts (27), two loop clamps (25), two screws
(22), two lockwashers (24), and two nuts (23).
5.
Install 3 gaskets (18) and 3 connectors (17), using 12 screws (19) and 12 lockwashers (20).
0162 00-2