14. Disconnect connector (18) from generator blower (52).
15. Remove ground lead (19) from engine (36) by removing screw (53) and two lockwashers (54).
16. Disconnect connector (20) from left side manifold preheat coil (55).
17. Remove ground lead (21) from engine (36) by removing bolt (56) and two washers (57).
18. Disconnect connector (22) from engine high oil temperature switch (58).
19. Disconnect connector (23) from engine oil temperature sending unit (59).
20. Disconnect connector (24) from time totalizing meter (60).
21. Remove ground lead (25) by removing nut (61).
22. Disconnect connector (26) from engine oil pressure sending unit (62).