TM 9-2350-256-20-2
0224 00
Removal
1.
Remove 20 clamps (17) by removing screw (18) and lockwasher (19) from each.
2.
Disconnect two connectors (1 and 14) from bulkhead disconnect (20).
3.
Disconnect two connectors (2 and 3) from hydraulic pressure switch (21).
4.
Disconnect two connectors (4 and 5) from APU engine disconnect (22) by removing four screws (23), four lockwashers
(24), and four nuts (25) from each.
5.
Disconnect connector (6) from APU wiring harness (26).
6.
Disconnect connector (7) from batteries to master relay, voltage regulators, slave receptacle, and engine disconnect wiring
harness (27).
7.
Disconnect connector (8) from APU voltage regulator (28).
0224 00-3