TM 9-2350-256-20-2
0401 00
2.
Install cover assembly (8) with three screws (9) and three lockwashers (10).
3.
Rotate cylinder control valve shaft (15) and handle (16) counterclockwise to the reset position, and install safety pin (7)
through handle and cover assembly (8).
4.
Install safety seal (6).
5.
Inspect two fire extinguisher control valves to be sure pin (17) does not extend beyond shaft on side away from handle (16).
If it does, protruding pin must be driven back into shaft 0.062 inch (in.) (1.57 millimeters [mm] ). Then stake hole at three
places to prevent pin from coming through. File staking flush to ensure free rotation.
Install two cylinder control valves (3) into cylinders (5).
6.
Connect interconnecting tube assemblies (1 and 2) to cylinder control valves (3) and head assemblies (4).
7.
END OF WORK PACKAGE
0401 00-3/4 blank