TM 9-2350-256-20-2
0439 00
Removal
NOTE
Steps 1 thru 9 apply only to right side.
1.
Disconnect and remove cable assembly (4) from circuit breaker and switch assembly (2) and dome light (5).
2.
Remove ground wire (6) from M2A2 air purifier (3) by removing screw (7) and lockwasher (8).
3.
Remove circuit breaker and switch assembly (2) by removing two screws (9) and two lockwashers (10).
4.
Disconnect and remove rigger's hose (11) and commander's hose (12) from manifold of M2A2 air purifier (3) and clamps
(13).
5.
Remove circuit breaker and switch assembly (2) by removing two screws (9) and two lockwashers (10).
6.
Disconnect mechanic's hose (14) from clamp (15) and manifold of M2A2 air purifier (3). Remove six clamps (16) by
removing from each screw (17) and lockwasher (18).
7.
Remove two clamps (13) and clamp (15) by removing from each screw (19) and lockwasher (20).