10-1 REPLACE PERSONNEL HEATENR Continued
5 Install air circulation ventilator (15), four lockwashers (14), and four screws (13).
6 Install two saddle assemblies (10) with four screws (11) and four new lockwashers (12).
7 Install personnel heater (5) using two clamps (9). Do not tighten clamps. /
NOTE
Be sure that exhaust flange is properly alined before tightening clamps.
8 Install exhaust hose clamp (8) and tighten two clamps (9).
10-4
9. Install personnel heater hose (7) with two
clamps (6) on personnel heater (5).