CHAPTER 12: MAINTENANCE OF MAIN HYDRAULIC SYSTEMTM 9-2350-256-2012-2 HYDRAULIC LINES AND FITTNGS--ContinuedNOTEThe following table lists the equipment condition for removal of the hose in question.TABLE 12-5. EQUIPMENT CONDITIONSCalloutNumberCodeNumberHoseEquipment Conditions11614DLAir Inlet Doors (left side) opened (see paragraph 9-56)Batteries removed (see paragraph 6-4)Engine Deck removed (see paragraph 9-51) 11711725Left- and Center-Front Air Inlet Grilles removed (see paragraph 9-57)11944Air Cleaner (right) removed (see paragraph 4-24)Hydraulic Connection Access Cover removed (see paragraph 9-7)APU removedAir Inlet Doors (two front right side) opened (see paragraph 9-56)12012Air Cleaner (right) removed (see paragraph 4-24)Hydraulic Connection Access Cover removed (see paragraph 9-7)APU removedLeft- and Center-Front Air Inlet Grilles (far right) removed (see paragraph 9-57)12113AAir Cleaner (right) removed (see paragraph 4-24)Hydraulic Connection Access Cover removed (see paragraph 9-7)APU removedEngine Deck removed (see paragraph 9.-51)Air Inlet Doors (two front right side) opened (see paragraph 9-56)Clamp (118) removed Section G-G12252AAir Cleaner (right) removed (see paragraph 4-24)Hydraulic Connection Access Cover removed (see paragraph 9-7)APU removedEngine Deck removed (see paragraph 9-51)Cover (137) removed Section J-JRight Deck Air Inlet Door removed (see paragraph 9-60)12351BAir Cleaner (right) removed (see paragraph 4-24)Hydraulic Connection Access Cover removed (see paragraph 9-7)APU removedEngine Deck removed (see paragraph 9-51)Air Inlet Doors (right side) opened (see paragraph 9-56)Covers (136 and 137) removed Section I-I and Section J-J12419AAir Cleaner (right) removed (see paragraph 4-24)Hydraulic Connection Access Cover removed (see paragraph 9-7)APU removedEngine Deck removed (see paragraph 9-51)Air Inlet Doors (two front right side) opened (see paragraph 9-56)Cover (137) removed Section J-JRight Deck Air Inlet Door removed (see paragraph 9-60)12514DRAir Cleaner (right) removed (see paragraph 4-24)Hydraulic Connection Access Cover removed (see paragraph 9-7)APU removedEngine Deck removed (see paragraph 9-51)Air Inlet Doors (right side) opened (see paragraph 9-56)12-22
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business