TM 9-2350-256-20Connector No.Electrical Lead To: Wire No.1Flasher assembly2GroundGND3Directional signal control wiring harness (12322611)A4Directional signal control wiring harness (12322611)Ba. REMOVAL1Disconnect connector (1) from flasher (5).2Disconnect ground lead (2) by removing screw (6) and two lockwashers (7).3Disconnect two connectors (3 and 4).b. DISASSEMBLYDisassemble wiring harness (see Chapter 6, SectionVI).c. ASSEMBLYAssemble wiring harness (see Chapter 6, Section VII).d. INSTALLATION1Connect two connectors (3 and 4).2Connect ground lead (2) using screw (6) and two new lockwashers (7).3Connect connector (1) to flasher (5).H— 13