SECTION V: TROUBLESHOOTINGTM 9-2350-256-20WARNINGRemove all jewelry such as rings, dogtags, bracelets, etc. If jewelry contacts ametal surface a direct short may result ininstant heatingof tools, damage toequipment, and injury or death topersonnel.MReconnect bulkhead to APU, master relay, and rigger'slights wiring harness to bulkhead disconnect. Opencenter-front air inlet doors (TM 9-2350-256-10).Disconnect bulkhead to APU, master relay, and rigger'slights wiring harness from APU engine disconnect.Place red lead of multimeter on pin B of wire 420A andblack lead to ground. Turn MASTER and APU FUELSHUTOFF switches ON and check for voltage. TurnMASTER and APU FUEL SHUTOFF switches OFF. Ifvoltage is present, notify Direct Support Maintenance.If voltage is not present, repair/replace wire 420A ofbulkhead to APU, master relay, and rigger's lightswiring harness (see paragraph 6-75 for dual voltage; 6-76 for single voltage).2-181