TM 9-2350-256-34
0008 00
CORRECTIVE ACTION Continued
33. Inspect hoses and fittings for visible indication of oil leaks. Repair or replace hoses and fittings (WP
34. Inspect level winder valve spool and cylinder rod for leaks.
a.
b.
35. Inspect level winder control valve actuating mechanism for broken parts.
a.
b.
36. Inspect level winder for improper adjustment (evident by uneven wrap of cable).
a.
END OF WORK PACKAGE