TM 9-2350-256-34
0015 00
CORRECTIVE ACTION Continued
5.
Test for faulty or improperly adjusted relief valve within system selector valve. Install pressure gage in
system selector valve gage port. With APU operating, and APU emergency winch control valve lever
placed in CLOSED position, place system selector valve lever in AUX position, and adjust relief valve.
a.
Adjust relief pressure to 14501550 psi (999810,687 kPa). For location of valve gage port and
b.
Replace system selector valve if pressure cannot be adjusted to 14501550 psi (999810,687 kPa)
NOTE
Perform the following tests using main hydraulic system (step 6 only).
6.
Test spade combination control valve, and spade cylinders. Refer to steps 13, 14, and 15, in SPADE
CIRCUIT (MAIN HYDRAULIC SYSTEM) TROUBLESHOOTING PROCEDURE.
END OF WORK PACKAGE
0015 00-2