TM 9-2350-256-34
0017 00
CORRECTIVE ACTION Continued
valve lever placed in CLOSED position, place system selector valve lever in AUX position, and adjust
relief valve.
a.
Adjust relief pressure to 14501550 psi (999810,687 kPa). For location of valve gage port and
b.
Replace system selector valve if pressure cannot be adjusted to 14501550 psi (999810,687 kPa)
5.
Inspect adjustable flow regulator lever for improper setting, or faulty adjustable flow regulator. Refer
to TM 9-2350-256-10 for proper setting.
a.
If adjustable flow regulator lever is properly set, and impact wrench does not operate, replace ad-
6.
Inspect fuel transfer pump control valve lever for improper position.
a.
Place fuel transfer pump control valve lever in CLOSED position.
7.
Inspect impact wrench for oil leaks or unusual noise.
a.
If impact wrench leaks oil, or is noisy, replace impact wrench.
b.
If impact wrench does not leak oil, or is not noisy, and still fails to operate, replace impact wrench.
END OF WORK PACKAGE
0017 00-2