The refuel/defuel pump is used when fueling the vehicle from drums or from another vehicle. It is also used to
transfer fuel from the M88A2 to another vehicle. The refuel/defuel pump is hydraulically driven and is powered by
the auxiliary hydraulic system. The controls and fuel hoses for refuel/defuel pump are in right side stowage
compartment on outside of the vehicle.
WARNING
JP8 is flammable. Do not perform this procedure near fire, flame or sparks. Personnel are
not allowed to smoke within 50 feet (15m). Failure to comply may result in injury or DEATH to
personnel.
Fuel and oil are slippery and can cause falls. Clean up spilled fuel with rags. Dispose of
fuel--soaked rags in accordance with unit policy. Failure to comply may result in injury to
personnel.
1. Set the FUEL CONTROL VALVES for the REFUEL/DEFUEL position (WP 0020 00).
2. Set the FUEL PUMP CONTROL handle (1) to CLOSED.
3. Move the FLOW REGULATOR handle (2) to the 10 position.
4. Select filler tube for desired operation, long tube (3) for refuel and short tube (4) for defuel.
5. Place filter (5) in filler tube (3 or 4), remove dust cap (6) and screw the tube onto the nozzle (7) hand tight (if
leakage occurs the tube may be slightly tightened by wrench).
6. Remove fuel hose connection cap (8) and fuel hose plug (9) and connect the fuel hose (10) to fuel hose connector
(11).