Home
Download PDF
Order CD-ROM
Order in Print
AUXILIARY POWER UNIT TROUBLESHOOTING
BRAKES TROUBLESHOOTING
TM-9-2350-292-10 Carrier Ammunition Tracked M992A1(NSN 2360-01-362-3021) EIC:AE6 Manual
Page Navigation
225
226
227
228
229
230
231
232
233
234
235
TM 9--2350--292--10
BILGE PUMP TROUBLESHOOTING (WHEN INSTALLED)
0085 00
THIS WORK PACKAGE COVERS:
Bilge pump does not pump water
0085 00--1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bilge pump fails to operate
0085 00--1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INITIAL SETUP:
Personnel Required
Three
BILGE PUMP DOES NOT PUMP WATER
Step 1. Check for a clogged bilge pump inlet.
Remove obstruction from pump inlet. If failure is due to clogged pump screen, notify unit maintenance.
Step 2. Check for a clogged bilge pump vent.
Remove obstruction from pump vent.
Step 3. If problem still exists, notify unit maintenance (BILGE PUMP FAILS TO OPERATE).
BILGE PUMP FAILS TO OPERATE
Step 1. Reset bilge pump
circuit breaker
switch on Accessory/PTO panel.
Step 2. If problem still exists, notify unit maintenance (BILGE PUMP FAILS TO OPERATE).
END OF TASK
0085 00--1/2 blank
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business