TM 9--2350--292--10
0101 00--84
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
0101 00
TABLE 6 LUBRICATION INSTRUCTIONS -- CONTINUED
15. HYDRAULIC RESERVOIR OIL LEVEL CHECK (C)
WARNING
CAUTION
Do not over fill hydraulic reservoir with boom in
down position. when boom is raised, hydraulic fluid
will overflow out of the bayonet gage neck. Overfil-
ling may cause damage to equipment.
Park vehicle on a level surface. Remove two screws, two
flat washers, and subfloor access plate. Remove bayonet
gage, wipe clean and insert. Remove bayonet gage and
verify oil is above the DANGER mark. If required, remove
filler cap and add proper grade oil (WP 0101 00--65) to bring
oil level above DANGER mark. Insert bayonet gage. Start
main engine (WP 0012 00) and operate hydraulic system
until hydraulic oil is at operating temperature. Shut off main
engine (WP 0019 00). Remove bayonet gage and verify that
oil level on HOT side of bayonet gage reaches the lower
FULL mark with the boom down or the upper FULL mark
with the boom up. If required, remove filler cap and add
additional oil. Install filler cap and bayonet gage. Install
subfloor access plate.
BOOM UP FULL HOT BOOM DOWN
DANGER
SUBFLOOR ACCESS PLATE
BAYONET GAUGE
FILLER CAP