TM 9--2350--292--100005 00--6THEORY OF OPERATION -- CONTINUED0005 00FIXED FIRE EXTINGUISHER SYSTEM (FES)DDualPullMechanism (1) -- connects the two sets of remote control pull handles (3 and 6) to the cylindercontrol valves (4) via cables.DEngineShutoffSwitch (2) -- closes the fuel shutoff solenoid valve in the fuel system when the interiorremote control pull handle (3) shield is released. This action shuts down the main engine if it is running.Refer to WP 0000 00 for operation.DInteriorRemoteControlPullHandles (3) -- discharge the FES when pulled.DCylinderControlValve (4) -- controls the discharging of the cylinder banks. The cylinder control valvesare operated by the remote control pull handles or manually by moving the lever.DCO2Cylinder (5) -- eight 10--lb cylinders are located in two banks of four cylinders each on the left andright sides of the crew compartment. Each bank is connected to a cylinder control valve (4).DExteriorRemoteControlPullHandles (6) -- discharge the FES when pulled.123456