TM 9--2350--292--20--1
BATT/GEN GAUGE READS IN YELLOW OR LOWER RED WITH APU
RUNNING AND APU GEN SWITCH ON -- CONTINUED
0013 00
Is continuity present?
Place one multimeter lead in harness 3W702
J1 socket H and other lead on harness 3W702
P2 pin C. Check for continuity.
Q
no
yes
Repair (WP 0290 00) or
replace (WP 0311 00)
harness 3W702. Verify
fault is corrected.
Replace APU voltage
regulator (WP 0239 00).
Verify fault is corrected.
Is continuity present?
1. Disconnect lead 478A from generator/starter
terminal D.
2. Place one multimeter lead on lead 478A
connector and other lead on harness 3W711
pin H. Check for continuity.
no
yes
R
Repair (WP 0290 00) or
replace (WP 0648 00)
harness 3W711. Verify
fault is corrected.
CONTINUED FROM STEP P
END OF TASK
0013 00--9/10 blank