TM 9--2350--292--20--10020 00--2PACKET NAME AUXILIARY POWER UNIT ENGINE HARD TO START INCOLD WEATHER -- CONTINUED0020 00Is 4.75 + 1.5 ohms indicated?noyesBReplace glow plug(WP 0629 00).Verify fault iscorrected.CONTINUED FROM STEP AFault corrected.1. Reconnect lead 3W732 lead to preheaterrelay.2. Place one multimeter lead on glow plug andother lead to ground.3. Check for resistance.4. Reconnect lead 3W732 to glow plug.END OF TASK