TM 9--2350--292--20--10059 00--2ENGINE STARTER CRANKS WHEN MASTER SWITCH IS TURNED ON ORENGINE STARTER FAILS TO SHUT OFF WHEN ENGINE IS RUNNING --CONTINUED0059 00noyesReplace module (WP0241 00). Verify fault iscorrected.1. Reconnect starter low voltage protectionmodule.2. Place one multimeter lead on lead 82connector at starter solenoid and other leadon solenoid bus bar connector. Check forcontinuity.BIs continuity present?Replace starter lowvoltage protectionmodule (WP 0241 00).Verify fault is corrected.Replace starter (WP0246 00). Verify faultis corrected.yesnoCONTINUED FROM STEP AnoyesGo to WP 0041 00 andperform Steps P thru U.Is continuity present?1. Reconnect harness 4W101 P1 to switchpanel receptacle.2. Disconnect connector from starter low voltageprotection module.3. Place one multimeter lead on module pin Band other lead on module pin D. Check forcontinuity.CEND OF TASK