TM 9--2350--292--20--1
0059 00--2
ENGINE STARTER CRANKS WHEN MASTER SWITCH IS TURNED ON OR
ENGINE STARTER FAILS TO SHUT OFF WHEN ENGINE IS RUNNING --
CONTINUED
0059 00
no
yes
Replace module (WP
0241 00). Verify fault is
corrected.
1. Reconnect starter low voltage protection
module.
2. Place one multimeter lead on lead 82
connector at starter solenoid and other lead
on solenoid bus bar connector. Check for
continuity.
B
Is continuity present?
Replace starter low
voltage protection
module (WP 0241 00).
Verify fault is corrected.
Replace starter (WP
0246 00). Verify fault
is corrected.
yes
no
CONTINUED FROM STEP A
no
yes
Go to WP 0041 00 and
perform Steps P thru U.
Is continuity present?
1. Reconnect harness 4W101 P1 to switch
panel receptacle.
2. Disconnect connector from starter low voltage
protection module.
3. Place one multimeter lead on module pin B
and other lead on module pin D. Check for
continuity.
C
END OF TASK