TM 9--2350--292--20--1THE NON--VOLATILE CALIBRATION DATA STORED IN REMOTE TERMINALUNIT FAILED AN INTERNAL CONSISTENCY CHECK AFTER BEING READ0063 00THIS WORK PACKAGE COVERS:The Non--Volatile Calibration Data Stored In Remote Terminal Unit Failed An Internal Consistency Check AfterBeing ReadINITIAL SETUP:Tools and Special ToolsSPORT with Enhanced Diagnostics System softwareloaded (item 133, WP 0717 00)Equipment ConditionsVehicle MASTER switch ON (TM 9--2350--292--10)SPORTconnected to Enhanced Diagnostic Systemremote terminal (WP 0086 00)Enhanced Diagnostic System POWER switch ONHas the remote terminal unit been replaced andthen calibrated after replacement?AnoyesCalibrate remoteterminal unit (WP0692 00). Verifyfault is corrected.Replace remoteterminal unit (WP0675 00). Verifyfault is corrected.FORWARDaEND OF TASK0063 00--1/2 blank