TM 9--2350--292--20--10140 00--4PERSONNEL HEATER FAILS TO OPERATE PROPERLY -- CONTINUED0140 00IIs 24 V dc present?CONTINUED FROM STEP Hnoyes1. Reconnect leads to 20 amp circuit.2. Reconnect lead 400 to heater control box.3. Disconnect wiring harness 4W124 at personnelheater.4. Turn MASTER switch and HEATER CONTROLswitch ON (TM 9--2350--292--10).5. Place red multimeter lead in wiring harness4W124 personnel heater connector socket Eand black lead to ground. Check for voltage.6. Turn MASTER switch and HEATER CONTROLswitch OFF (TM 9--2350--292--10).Replace personnel heater(WP 0529 00). Verify faultis corrected.JIs continuity present?noyes1. Place HEAT switch in HI position(TM 9--2350--292--10).2. Place one multimeter lead on HEATERCONTROL switch terminal 19 and other leadon HI terminal of HEAT switch. Check forcontinuity.Repair (WP 0290 00) or re-place lead to HEAT switch(WP 0248 00). Verify faultis corrected.CONTINUED ON NEXT PAGE