TM 9--2350--292--20--10140 00--3PERSONNEL HEATER FAILS TO OPERATE PROPERLY -- CONTINUED0140 00GIs continuity present?CONTINUED FROM STEP F1. Disconnect leads from other side of 20--ampcircuit breaker.2. Place one multimeter lead in each circuitbreaker connector socket. Check for continuity.yesnoReplace 20--amp circuitbreaker (WP 0248 00).Verify fault is corrected.Replace indicator socketand cable (WP 0248 00).Verify fault is corrected.HIs continuity present?CONTINUED FROM STEP A1. Disconnect lead 400 from heater control box.2. Open heater control box and disconnect leadsfrom indicator side of 20--amp circuit breaker.3. Place one multimeter lead on HEATERCONTROL switch terminal 15 and other leadon lead terminal to circuit breaker. Check forcontinuity.yesnoRepair (WP 0290 00) or re-place (WP 0248 00) lead fromcircuit breaker to switch. Verifyfault is corrected.CONTINUED ON NEXT PAGE