TM 9--2350--292--20--10162 00--2VENTILATING BLOWER FAILS TO OPERATE. ALL OTHER SYSTEMSOPERATE PROPERLY -- CONTINUED0162 00noyesC1. Remove accessory control panel cover(WP 0244 00).2. Place one multimeter lead on terminal 1 ofswitch S2 and other lead on accessory controlpanel receptacle J3 pin B. Check for continuity.Is continuity present?Repair (WP 0290 00) or replace(WP 0244 00) lead 59 from panelreceptacle J3 pin B to switch S2.Verify fault is corrected.CONTINUED FROM STEP BnoyesDPlace one multimeter lead on each terminalconnector of switch S2. Check for continuity.Is continuity present?Replace switch S2(WP 0244 00).Verify fault iscorrected.Replace TB1 (WP 0244 00).Verify fault is corrected.noyesEPlace one multimeter lead on switch S2 terminal 2and other lead on terminal board 1 (TB1) terminal 3.Check for continuity.Is continuity present?Replace lead 59 fromTB1 to switch S2(WP 0244 00). Verifyfault is corrected.END OF TASK