TM 9--2350--292--20--10163 00--2VENTILATING BLOWER WILL NOT OPERATE AT FULL SPEED --CONTINUED0163 00yesnoReplace generator(WP 0237 00). Verifyfault is corrected.CIs VTM reading between 25.8 and 30.2 V dc?CONTINUED FROM STEP BPerform STE--ICE--R test 82(TM 9--4910--571--12&P) and record results.DIs air passage obstructed?Check ventilating blower air passage for obstruc-tions.yesnoGo to WP 0162 00.Clear away obstruc-tions. Verify fault iscorrected.CONTINUED FROM STEP AEND OF TASK