TM 9--2350--292--20--1
0171 00--2
SYSTEM WARNING LIGHT DOES NOT LIGHT WHEN MAIN WINCH
MALFUNCTIONS -- CONTINUED
0171 00
CONTINUED FROM STEP B
1. Remove gauge panel from bracket
(WP 0243 00).
2. Disconnect harness 4W103 P1 from gage
panel.
3. Place one multimeter lead in harness 4W103
P1 socket D and other lead on harness 4W618
P1 pin 24. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0316 00)
harness 4W103. Verify
fault is corrected.
Replace relay K2
(WP 0244 00). Verify
fault is corrected.
Is continuity present?
Place one multimeter lead on terminal junction T20
connector K and other lead on relay K1 connector
A2. Check for continuity.
C
D
no
yes
Replace lead 509 to
relay K1 (WP 0244 00).
Verify fault is corrected.
END OF TASK