TM 9--2350--292--20--10176 00--2SYSTEM WARNING INDICATOR WILL NOT COME ON WHEN ACTIVATINGWINCH TEST SWITCH -- CONTINUED.0176 00CIs continuity present?CONTINUED FROM STEP Bnoyes1. Disconnect harness 4W618 connector P2 fromharness 4W617 connector J1 (WP 0331 00).2. Place one multimeter lead in harness 4W617lead 359 connector and other multimeter leadin harness 4W617 connector J1 socket J.Check for continuity.Repair (WP 0290 00) orreplace (WP 0330 00)harness 4W617. Verifyfault is corrected.DIs continuity present?noyes1. Disconnect harness 4W618 connector P1 fromPTO/accessory panel (WP 0331 00).2. Place one multimeter lead on harness 4W618connector P2 pin J and other lead in harness4W618 connector P1 socket 8. Check forcontinuity.Repair (WP 0290 00) orreplace (WP 0331 00)harness 4W618. Verifyfault is corrected.CONTINUED ON NEXT PAGEEIs continuity present?noyes1. Open PTO/accessory panel (WP 0244 00).2. Place one multimeter lead on panel connectorJ2 pin 8 and other lead on terminal board T14terminal A. Check for continuity.Replace lead 359 fromconnector J2 pin 8 to ter-minal board T14 terminalA (WP 0244 00). Verifyfault is corrected.