TM 9--2350--292--20--10009 00--3AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0009 00noyesRepair (WP 0290 00) or replace(WP0648 00) harness 3W711.Verify fault is corrected.CONTINUED FROM STEP DIs continuity present?1. Disconnect lead 487 at preheater relay anddisconnect harness 3W711 P1 at APUengine disconnect.2. Place one multimeter lead on lead 487 andplace other lead on pin D of harness 3W711P1. Check for continuity.FIs continuity present?1. Reconnect lead 487 at preheater relay.2. Open air intake grilles above batterycompartment (TM 9--2350--292--10).3. Disconnect harness 3W702 P1 at bulkheaddisconnect.4. Place one multimeter lead in socket D of3W702 J1 and other lead in harness 3W702 P1socket B. Check for continuity.GnoyesRepair (WP 0290 00) or replace(WP 0311 00) harness 3W702.Verify fault is corrected.Is continuity present?1. Reconnect harness 3W711 P1 at APU enginedisconnect.2. Disconnect harness 4W700 P1 at APU controlbox.3. Disconnect harness 4W700 P2 from bulkheaddisconnect.4. Place one multimeter lead on pin B of harness4W700 P2 and other lead in socket A of harness4W700 P1. Check for continuity.HnoyesRepair (WP 0290 00) or replace(WP 0332 00) harness 4W700.Verify fault is corrected.CONTINUED ON NEXT PAGE