TM 9--2350--292--20--10009 00--4AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0009 00Is continuity present?Place one multimeter lead in harness 4W700 P1socket C and place other lead to vehicle ground.Check for continuity.noyesIRepair (WP 0290 00) or replace(WP 0322 00) ground lead fromcontrol box connector to ground.Verify fault is corrected.CONTINUED FROM STEP HIs continuity present?1. Turn APU control box switch ON(TM 9--2350--292--10).2. Place one multimeter lead on APU control boxreceptacle pin D and other lead on APU controlbox receptacle pin B. Check for continuity.noyesJNotify Direct SupportMaintenance.CONTINUED ON NEXT PAGE