TM 9--2350--292--20--1
0187 00--55
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, MONTHLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
MONTHLY
INTERIOR
14
Bearing Plate
Lube Fitting Bank
a. Remove subfloor plates #2, #3 and #4
(1) (WP 0454 00).
LUBRICANTS
/
COMPONENTS
REFILL
CAPACITY
EXPECTED TEMPERATURE*
+40°F to --10°F
(+4°C to --23°C)
Above +32°F
(Above 0°C)
0°F to --65°F
(--17°C to --54°C)
GREASE:
Automotive and
Artillery Grease,
(GAA),
MIL--G--10924
As
Required
*For Arctic Operation, refer to FM 9--207
ALL TEMPERATURES
b. Lubricate with GAA through four fittings
(2) until grease is visible.
c. Wipe excess grease with rag
(item 7, WP 0716 00).
d. Install subfloor plates #2, #3 and #4 (1)
(WP 0454 00).
Clogged,
damaged or
missing
grease
fittings.
1
2
1