TM 9--2350--292--20--1
0187 00--132
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
SEMIANNUALLY
EXTERIOR
42
Stayline Pins
LUBRICANTS/
COMPONENTS
REFILL
CAPACITY
EXPECTED TEMPERATURE*
+40°F to --10°F
(+4°C to --23°C)
Above +32°F
(Above 0°C)
0°F to --65°F
(--17°C to --54°C)
GREASE:
Automotive and
Artillery Grease,
(GAA),
MIL--G--10924
As
Required
*For Arctic Operation, refer to FM 9--207
ALL TEMPERATURES
a. Lubricate two stayline pins (1) with
GAA through two fittings (2) until grease is
visible.
b. Wipe excess grease with clean rag
(item 7, WP 0716 00).
Any clogged,
missing or
damaged
grease
fittings.
1
2