TM 9--2350--292--20--1
0187 00--144
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
SEMIANNUALLY
EXTERIOR
55
Auxiliary Power
Unit (ONAN)
a. Open auxiliary power unit access door
(1) (TM 9--2350--292--10).
LUBRICANTS/
COMPONENTS
REFILL
CAPACITY
EXPECTED TEMPERATURE*
+40°F to --10°F
(+4°C to --23°C)
Above +32°F
(Above 0°C)
0°F to --65°F
(--17°C to --54°C)
OIL:
Lubricating Oil,
OE/HDO
MIL--L--2104 or
OEA MIL--L--46167
3.5 qt
(3.31L)
15 W40 or
OE/HDO--30
(0--237)
OE/HDO--10
(0--237)
OEA
(0--183)
*For Arctic Operation, refer to FM 9--207
b. Replace oil filter (2) (WP 0596 00).
Check engine oil level gauge (3), which
should indicate full. Add oil as required.
Any Class
III leak or
low engine
oil level.
1
3
2