TM 9--2350--292--20--2
0680 00--4
WIRING HARNESS 4W504 REPLACEMENT -- CONTINUED
0680 00
Installation--Continued
NOTE
The following legend identifies attachment points for each
connection.
2. Install wiring harness (1) with attaching hardware, at the following attachment points:
Item
No
4W504
Connector/Lead/Wire
To
Connector/Lead/Wire
Component
Location
6
Connector J1
Wiring Harness 2W505 Connector
P1
Beneath Subfloor
5
Connector P4
Hoist Winch Transducer 4MT545
Beneath Subfloor
4
Connector P3
Boom Shutoff Valve Transducer
4MT542
Beneath Subfloor
3
Connector P2
Boom Shutoff Valve Transducer
4MT543
Beneath Subfloor
2
Connector P1
Remote Terminal Unit Connector J2
Crew Compartment (Left Side,
Behind Ammunition Rack)
3
4
6
5
2
1
NOTE
FOLLOW--ON MAINTENANCE:
Install subfloor plate #13 (WP 0454 00)
Install main winch and spade assembly (WP 0497 00)
END OF TASK