TM 9--2350--292--20--20684 00--2HYDRAULIC CONTROL VALVE MANIFOLD ASSEMBLY SWITCH,TRANSDUCERS AND ASSOCIATED PARTS REPLACEMENT -- CONTINUED0684 00NOTETo replace transducer 4MT522 perform removal steps 38through 41 and 46 and installation steps 5 through 8.To replace transducer 4MT523 perform removal steps 42through 46 and installation steps 1 through 4.RemovalWARNINGWARNINGWARNINGHydraulic system pressure is rated 4450 psi. Do nottorque hydraulic fittings or perform removal procedureswhen hydraulic system is pressurized. Discharging sys-tem pressure before performing any maintenance proce-dures will avoid injury to personnel.Eye protection will be worn when performing mainte-nance procedures on all hydraulic components to avoidinjury to personnel.CAUTIONCap all hydraulic lines and plug all hydraulic ports to pre-vent contamination. Failure may result in damage to hy-draulic system.All serviceable components must be placed in plasticbags to prevent contamination of hydraulic system duringinstallation.NOTEAll hydraulic lines and components must be tagged be-fore removal for identification during installation.Place rags under hydraulic connections to catch any hy-draulic fluid that spills during maintenance. Dispose offluid soaked rags in accordance with standard operatingprocedure.