Installation--Continued
16. Install new preformed packing (10) on hose (3).
17. Install hose (3), reducer (7), nut (8) and tee (6) in thermostic valve (9) port C.
18. Connect one end of hose (4) to tee (6) and other end to bulkhead connector (5).
19. Install transducer 4MT524 (2) on hose (3).
20. Install wiring harness 4W503 connector P2 (1) on transducer 4MT524 (2).
1
2
3
4
5
6
9
10
7
8
NOTE
FOLLOW--ON MAINTENANCE:
Calibrate new transducers (WP 0692 00)
Start engine, operate main and hoist winch hydraulic
controls several times to purge air from hoses
(TM 9--2350--292--10)
Check hydraulic system for leaks and fill hydraulic reser-
voir (TM 9--2350--292--10)
Install floor plate #20 and #22 (WP 0454 00)
END OF TASK