TM 9--2350--292--20--2
0691 00--3
LEFT AND RIGHT SIDE BOOM LIMIT VALVE TRANSDUCER, SWITCHES AND
ASSOCIATED PARTS REPLACEMENT -- CONTINUED
0691 00
Removal--Continued
1. Remove wiring harness 3W501 connector P2 (1) from switch 3S510 (2).
2. Remove switch 3S510 (2) with straight swivel adapter (3) from straight adapter (4) then remove straight swivel
adapter (3) from switch 3S510 (2).
3. Remove hose (5) from straight swivel adapter (6).
4. Remove straight swivel adapter (6), straight adapter (4), tee (7) from right side boom limit valve (8).
5. Remove preformed packing (9) from straight swivel adapter (3). Discard preformed packing.
1
2
3
4
5
6
7
8
9