TM 9--2350--292--20--20565 00--2HYDRAULIC PUMP HYDRAULIC LINES AND FITTINGS REPLACEMENT --CONTINUED0565 00Removal--ContinuedWARNINGHydraulic system pressure is rated 4450 psi. Do nottorque hydraulic fittings or perform removal procedureswhen hydraulic system is pressurized. Discharging sys-tem pressure before performing any maintenance proce-dures will prevent injury to personnel.Eye protection will be worn when performing mainte-nance procedures on all hydraulic components to preventinjury to personnel.CAUTIONCap all hydraulic lines and plug all hydraulic ports to pre-vent contamination. Failure to comply may result in dam-age to hydraulic system.All serviceable components must be placed in plasticbags to prevent contamination of hydraulic system duringinstallation.NOTEAll hydraulic lines and components must be tagged be-fore removal for identification during installation.Place rags under hydraulic connections to catch any hy-draulic fluid that spills during maintenance. Dispose offluid--soaked rags in accordance with standard operatingprocedure.1. Remove hose assemblies, lines and fittings in accordance with the following legend and illustration. Discard lock-washers and preformed packings.2. Inspect parts for damage and replace as required.Installation1. Apply sealing compound to all male pipe threads before installation of the component.2. Apply a thin even coat of clean lubricant to all new preformed packings prior to installation.3. Install hose assemblies, lines, fittings, new lockwashers and new preformed packings in accordance with the fol-lowing legend and illustration.NOTEFOLLOW--ON MAINTENANCE:Install subfloor plates #20, #21 and #22(WP 0454 00)