TM 9--2350--292--20--2
0587 00--3
AUXILIARY POWER UNIT ASSEMBLY REPLACEMENT (HATZ) -- CONTINUED
0587 00
Removal--Continued
NOTE
Perform the following steps to disconnect APU intake air
hose from APU assembly.
7. Loosen clamp (16) at air cleaner adapter (17). Slide clamp (16) back over hose (18) and remove hose (18) from
air cleaner adapter (17).
8. Loosen clamp (19). Slide clamp (19) back over hose (18). Remove hose (18) from elbow (20).
20
19
18
16
17