9. Remove two screws (21), two lockwashers (22), two flat washers (23) and cover (24). Discard lockwashers.
10. Loosen clamp (25). Slide clamp (25) back over air duct hose (26) and remove metal grille (27) and clamp (25).
25
27
23
22
21
24