TM 9--2350--292--20--1
0086 00--2
HYDRAULICS SYSTEM OVERVIEW AND DIAGRAMS -- CONTINUED
0086 00
Enhanced Diagnostics System Setup:
1. Connect wiring harness 4W508 connector P1 to remote terminal (RT) unit connector J6.
2. Connect wiring harness 4W508 connector P3 to SPORT 1553 data bus wire branch A.
3. Connect one end of SPORT power cable (part number 54418/711967) to wiring harness 4W508 connector P2
and other end to SPORT power connector.
4. Turn vehicle MASTER switch ON.
5. Turn RT unit circuit breaker switch ON. Power light will indicate RT unit is powered up.
6. Turn on SPORT.
7. Using the mouse, click on the START button in the taskbar.
8. Using the mouse, click on PROGRAMS, then on EDS, then on EDS again.
9. The Enhanced Diagnostics System program will open and display the selftest results then proceed to the
troubleshooting symptoms screen.
10. Click on Test in the menu then on Selftest in the dropdown menu to view selftest results. Click the Close button
to close the Selftest window.
11. Select the symptom to troubleshoot with either the mouse or the arrow keys.
12. The hydraulic pressure data screen for that symptom will be displayed and ready for use in conjunction with the
technical manual troubleshooting procedures.
FORWARD
END OF TASK