TM 9--2350--292--20--2
0641 00--2
AUXILIARY POWER UNIT RELAY AND MOUNTING BRACKET
REPLACEMENT (HATZ) -- CONTINUED
0641 00
Removal--Continued
3. Remove screw (11), two lockwashers (12), lockwasher (13), nut (14) and lead assembly 3W706 (15) from relay
terminal A1 (16). Discard lockwashers.
4. Remove screw (17), two lockwashers (18), lockwasher (19), nut (20), wiring harness 3W711 wire 66 (21) and wire
N (22) and wiring harness 3W730 wires 134 (23) and 135A (24) from relay terminal A2 (25). Discard lockwashers.
5. Remove two screws (26), two lockwashers (27) and relay (28) from mounting bracket (29).
6. Inspect parts for damage and replace as required.
20
11
12
15
12
16
13
14
17
18
19
21
18
22
23
24
27
26
25
28
29