TM 9--2350--292--20--2
0692 00--4
TRANSDUCER CALIBRATION -- CONTINUED
0692 00
Calibration--Continued
7. Using the mouse, click on the START button in the taskbar.
8. Select Programs, then EDS, then EDS again.
NOTE
If the RT unit has been replaced it will fail selftest when
the Enhanced Diagnostics System program is started.
The selftest results screen should only indicated the fol-
lowing fault.
The non--volatile calibration data stored in the RT failed
an internal consistency check after being read
If any other faults are indicated troubleshoot the En-
hanced Diagnostics System (WP 0060 00) before contin-
uing with transducer calibration.
9. The Enhanced Diagnostics System (EDS) program will open and display the troubleshooting symptoms screen
shown below.