TM 9--2350--292--20--2
0564 00--2
APU PRESSURE SWITCH REPLACEMENT -- CONTINUED
0564 00
Installation
1. Install APU pressure switch (5) in mounting bracket (6) with four screws (3) and four new lockwashers (4).
2. Connect APU pressure switch 3A720 electrical connector J1 (1) to wiring harness 3W702 connector P3 (2).
Figure 308
3
4
6
5
1
2
NOTE
FOLLOW--ON MAINTENANCE:
Install hydraulic lines and fittings on APU pressure
switch (WP 0581 00 or WP 0582 00)
Connect battery power (WP 0256 00)