SEMIANNUAL NOTES (CONTINUED)
Note 47
FINAL DRIVE DRAIN AND FILL
WARNING
Oil will be hot after operation.
Drain oil from both final drives.
Note
Drain only after operation.
A Remove level plug (1) and drain plug (2) and drain oil into a
suitable container.
WARNING
Dry cleaning solvent (SD2) is toxic and flammable.
Wear protective goggles and gloves and use only in
well-ventilated area.
B Clean drain plug (2) with solvent SD2 and install.
C Remove fill plug (3) in final drive saddle.
D Slowly add oil (OE/HDO or OEA) through fill plug hole (3) until
oil flows from level plug hole (1).
E Clean plugs (1) and (3) with solvent SD2 and install.
F Repeat steps A thru E for other side.
Note 48
SPADE CYLINDER HINGE PINS
A Remove pins.
WARNING
Dry cleaning solvent (SD2) is toxic and flammable.
Wear protective goggles and gloves and use only in
well-ventilated area.
B Clean pins with SD2.
C Lubricate with GAA and install.
D Wipe off excess grease.
SPADE CYLINDER HINGE
PINS
C a r d 27 of 40
LO 9-2350-238-12