TM 1-1680-320-13&P
0010 00
1. Place hoist assembly onto assembly stand (1) ensuring alignment of quick disconnect adapters (4) to stand
top and bottom studs.
2. Adjust height adjuster (5) and reaction arm (6) as required to secure hoist (3).
3.
Ensure that control panel position switch coincides with release pin.
4. Perform pre-operational checks in accordance with WP 0011 00.
HELICOPTER
WARNINGS
Ensure external electrical power is removed from system prior to installing
rescue hoist. Activated electricity could cause injury to personnel or damage
to equipment.
Do not connect the cannon plug to CAD until all electrical checks are
completed.
Enlist help of an assistant during installation to prevent injury or component
damage.
Rescue hoist shall be installed in accordance with UH-1 or UH-60 series helicopter maintenance manual.
0010 00-4