CAUTION
TM 9-2350-238-34-1
2 - 3 4 . M A I N T E N A N C E O F S L I P R I N G E L E C T R I C A L C O M P O N E N T S , S L I P R I N G D I S -
C O N N E C T T O I N T E R I O R D I S C O N N E C T W I R I N G H A R N E S S , A N D S L I P R I N G T O
2 4 - V O L T F E E D E L E C T R I C A L L E A D ( C O N T ) .
I N S T A L L A T I O N ( C O N T )
8
9
1
0
11
1
2
Install slip ring electrical contact set
assembly (12) in slip ring (3). Align
m o u n t i n g h o l e s.
Install eight new hexagon head capscrews
(16) to slip ring electrical contact set
assembly (12) and slip ring (3), and
secure with new Iockwire (17).
Connect slip ring electrical brush con-
nector assembly (18) to slip ring discon-
nect to interior disconnect wiring harness
( 7 ).
Use care not to drop any compres-
sion springs into slip ring.
Install 12 new compression springs (19) to
slip ring electrical contact set assembly
( 1 2 ).
Install slip ring electrical brush connector
assembly (18) into slip ring electrical
contact set assembly (12) using care not
to lose any compression springs (19).